ESMF_GridValidate Subroutine

public subroutine ESMF_GridValidate(grid, keywordEnforcer, rc)

Arguments

Type IntentOptional Attributes Name
type(ESMF_Grid), intent(in) :: grid
type(ESMF_KeywordEnforcer), optional :: keywordEnforcer
integer, intent(out), optional :: rc

Source Code

  subroutine ESMF_GridValidate(grid, keywordEnforcer, rc)
!
! !ARGUMENTS:
    type(ESMF_Grid), intent(in)              :: grid
type(ESMF_KeywordEnforcer), optional:: keywordEnforcer ! must use keywords below
    integer,         intent(out),  optional  :: rc
!
!
! !STATUS:
! \begin{itemize}
! \item\apiStatusCompatibleVersion{5.2.0r}
! \end{itemize}
!
! !DESCRIPTION:
!      Validates that the {\tt Grid} is internally consistent.
!      Note that one of the checks that the Grid validate does
!      is the Grid status. Currently, the validate will return
!      an error if the grid is not at least
!      {\tt ESMF\_GRIDSTATUS\_COMPLETE}. This means that
!      if a Grid was created with the {\tt ESMF\_GridEmptyCreate}
!      method, it must also have been finished with
!      {\tt ESMF\_GridEmptyComplete()}
!      to be valid. If a Grid was created with another create
!      call it should automatically have the correct status level
!      to pass the status part of the validate.
!      The Grid validate at this time doesn't check for the presence
!      or consistency of the Grid coordinates.
!      The method returns an error code if problems are found.
!
!     The arguments are:
!     \begin{description}
!     \item[grid]
!          Specified {\tt ESMF\_Grid} object.
!     \item[{[rc]}]
!          Return code; equals {\tt ESMF\_SUCCESS} if there are no errors.
!     \end{description}
!
!EOP
!------------------------------------------------------------------------------
    integer                 :: localrc      ! local return code

    ! initialize return code; assume routine not implemented
    localrc = ESMF_RC_NOT_IMPL
    if (present(rc)) rc = ESMF_RC_NOT_IMPL

    ! Check init status of arguments
    ESMF_INIT_CHECK_DEEP(ESMF_GridGetInit, grid, rc)

    ! Call into the C++ interface, which will sort out optional arguments.
    call c_ESMC_GridValidate(grid, localrc)
    if (ESMF_LogFoundError(localrc, ESMF_ERR_PASSTHRU, &
      ESMF_CONTEXT, rcToReturn=rc)) return

    ! return successfully
    if (present(rc)) rc = ESMF_SUCCESS